CEMENTED PROSTHETICS AND BURNOUT ABUTMENTS IGEA

Prosthetic components in Titanium Grade 23 and Cobalt-Chromium · For dental technicians and dental laboratories

Titanium Grade 23
Co-Cr Burnout
Torque 30 Ncm
Narrow M1.6 / Regular M2

WHY THIS PRODUCT

In the study and design of prosthetic components, Mesa has paid particular attention to offering optimal solutions to the clinician, in order to make the fabrication of prosthetic elements simple and flexible.

The maximum precision of each of our components contributes to ensuring the long-term success of the restoration. The IGEA component line covers the entire cemented restoration phase: straight, angled, temporary, emergence and burnout abutments, with dedicated prosthetic screws for Narrow (M1.6) and Regular (M2) connections.

The flexibility of prosthetic fabrication is guaranteed by the availability of abutments in Titanium Grade 23 for the standard component line and in Cobalt-Chromium for burnout abutments, which allow burnout casting with lost wax, digital modeling, welding and bonding of milled or melting structures.

WHO IT’S FOR

Designed for dental technicians and dental laboratories that perform cemented restoration on IGEA implants. Indicated for those who need precise and flexible components for single crowns, bridges, emergency solutions on supra-gingival implants and customizable burnout abutments.

DISTINCTIVE FEATURES

◎

Maximum component precision

Tight tolerances on every abutment → stable and repeatable restoration

⚙

Prosthetic fabrication flexibility

Straight, angled, temporary, emergence and burnout Co-Cr

✓

Long-term restoration success

Precision + biocompatibility Titanium Grade 23 and Cobalt-Chromium

⇄

Dual connection

Prosthetic screws M1.6 (Narrow) and M2 (Regular)

4.1 STRAIGHT TITANIUM ABUTMENTS – TITANIUM GRADE 23

The abutments screw directly onto the implant via the connection screw. They are used to support both single crowns and bridges. Available in non-rotating and rotating versions.

H1 mm H2 mm D mm Type Code
1 9 3.3 non-rotating CEM-1144
1 9 3.3 rotating CEM-1146
1 9 3.6 non-rotating CEM-1148
1 9 3.6 rotating CEM-1150
2.5 9 3.3 non-rotating CEM-1152
2.5 9 3.3 rotating CEM-1154
2.5 9 3.6 non-rotating CEM-1156
2.5 9 3.6 rotating CEM-1158
3 7 3.3 non-rotating CEM-1168
3 7 3.6 non-rotating CEM-1172
4 7 3.3 non-rotating CEM-1170
4 7 3.6 non-rotating CEM-1174
5 7 3.6 non-rotating CEM-1176

Non-sterile. Torque: 30 Ncm

Thread Code
M1.6 SCR-1400
M2 SCR-1401

Connection prosthetic screw. M1.6 = Narrow implants · M2 = Regular implants.

4.2 ANGLED TITANIUM ABUTMENTS – TITANIUM GRADE 23

Angled abutments at 15° and 25° with Hex A and Hex B hexagon, to manage axial divergences of the implant.

A° H1 mm H2 mm Hexagon Code
15° 1.8 6.0 Hex A CEM-1116
15° 1.8 6.0 Hex A CEM-1118
15° 1.8 6.0 Hex B CEM-1169
15° 1.8 6.0 Hex B CEM-1171
25° 1.6 7.0 Hex A CEM-1136
25° 1.6 7.0 Hex A CEM-1137
25° 1.6 7.0 Hex B CEM-1173
25° 1.6 7.0 Hex B CEM-1175

Non-sterile. Torque: 30 Ncm

Thread Code
M1.6 SCR-1400
M2 SCR-1401

Connection prosthetic screw. M1.6 = Narrow implants · M2 = Regular implants.

4.3 TEMPORARY TITANIUM ABUTMENTS – TITANIUM GRADE 23

Temporary abutments for transitional restoration fabrication. Available in non-rotating and rotating versions.

H1 mm H2 mm D mm Type Code
1 12 3.3 non-rotating CEM-1138
1 12 3.3 rotating CEM-1139
1 12 3.6 non-rotating CEM-1140
1 12 3.6 rotating CEM-1141

Non-sterile. Torque: 30 Ncm

Thread Code
M1.6 SCR-1400
M2 SCR-1401

Connection prosthetic screw. M1.6 = Narrow implants · M2 = Regular implants.

4.4 EMERGENCY TITANIUM ABUTMENTS – TITANIUM GRADE 23

Emergency abutments, also called rescue abutments, were designed for implants placed in the supra-gingival area.

H1 mm H2 mm D mm Type Code
1.3 7.7 3.5 non-rotating CEM-1160
1.3 7.7 3.5 rotating CEM-1161
1.3 7.7 3.8 non-rotating CEM-1162
1.3 7.7 3.8 rotating CEM-1163
1.3 7.7 4.3 non-rotating CEM-1164
1.3 7.7 4.3 rotating CEM-1165
1.3 7.7 5.0 non-rotating CEM-1166
1.3 7.7 5.0 rotating CEM-1167

Non-sterile. Torque: 30 Ncm

Thread Code
M1.6 SCR-1400
M2 SCR-1401

Connection prosthetic screw. M1.6 = Narrow implants · M2 = Regular implants.

4.5 BURNOUT ABUTMENTS IN Co-Cr – COBALT-CHROMIUM

They can be used for various solutions:

  • Burnout casting: with lost wax modeling or through digital modeling
  • Welding
  • Bonding of milled or melting structures
H1 mm H2 mm D mm Type Code
1 9 3.3 non-rotating OCA-1145
1 9 3.3 rotating OCA-1147
1 9 3.6 non-rotating OCA-1149
1 9 3.6 rotating OCA-1151
2.5 9 3.3 non-rotating OCA-1153
2.5 9 3.3 rotating OCA-1155
2.5 9 3.6 non-rotating OCA-1157
2.5 9 3.6 rotating OCA-1159

Non-sterile. Torque: 30 Ncm

Thread Code
M1.6 SCR-1400
M2 SCR-1401

Connection prosthetic screw. M1.6 = Narrow implants · M2 = Regular implants.

PROSTHETIC SCREWS

Abutment-implant connection screws for the entire IGEA prosthetic component line.

Thread Code Compatibility
M1.6 SCR-1400 IGEA Narrow implants
M2 SCR-1401 IGEA Regular implants

MATERIALS

Ti

Titanium Grade 23 (Ti-6Al-4V ELI)

Standard prosthetic components: straight, angled, temporary and emergency abutments. High biocompatibility, high mechanical strength.

CoCr

Cobalt-Chromium (Cr-Co)

Burnout abutments for lost wax casting, digital modeling, welding and bonding of milled or melting structures.

COMPATIBILITY

Connection Narrow (M1.6) – screw SCR-1400
Connection Regular (M2) – screw SCR-1401
Compatible implants IGEA (Mesa Italia line)
Tightening torque 30 Ncm
Condition Non-sterile

APPLICATIONS

  • Cemented single crowns
  • Bridges on IGEA implants
  • Lost wax burnout casting (Co-Cr abutments)
  • Digital modeling (Co-Cr burnout abutments)
  • Welding (Co-Cr abutments)
  • Bonding of milled or melting structures (Co-Cr abutments)
  • Emergency restoration on supra-gingival implants (emergency abutments)
  • Temporary restoration (temporary abutments)

FREQUENTLY ASKED QUESTIONS

What types of IGEA abutments are available?
The IGEA prosthetic component line includes five families: straight abutments in Titanium Grade 23 (CEM-1144 ÷ CEM-1176), angled abutments at 15° and 25° (CEM-1116 ÷ CEM-1175), temporary abutments (CEM-1138 ÷ CEM-1141), emergency abutments for supra-gingival implants (CEM-1160 ÷ CEM-1167) and burnout abutments in Cobalt-Chromium (OCA-1145 ÷ OCA-1159).
What is the torque for IGEA abutments?
All IGEA abutments (straight, angled, temporary, emergency and burnout) have a tightening torque of 30 Ncm. Supply condition: non-sterile.
What materials for the abutments?
Standard abutments (straight, angled, temporary, emergency) are in Titanium Grade 23 (Ti-6Al-4V ELI). Burnout abutments are in Cobalt-Chromium (Cr-Co), to allow burnout casting, welding and bonding of milled or melting structures.
When to use emergency abutments?
Emergency abutments (also called rescue abutments, CEM-1160 ÷ CEM-1167) are designed for implants placed in the supra-gingival area, where the standard component is not suitable. Available in diameters from 3.5 to 5.0 mm, non-rotating and rotating versions.
What to do with Co-Cr burnout abutments?
Burnout abutments in Cobalt-Chromium (OCA-1145 ÷ OCA-1159) can be used for various solutions: burnout casting with lost wax modeling or through digital modeling, welding and bonding of milled or melting structures. Torque 30 Ncm.

COMPLIANCE AND CERTIFICATIONS

Medical device
Titanium Grade 23
Cobalt-Chromium
Made in Italy

IGEA prosthetic components for cemented restoration. Compliance documentation available for customer audit.

READY FOR AN EVALUATION?

Request the IGEA component catalog, order codes or technical consultation. Mesa team responds within 48 business hours.

META & SOURCE (REF only)

Slug protesica-cementata-monconi-igea-ref
Canonical URL https://mesaitalia.it/en/igea-cemented-prosthetics-abutments-eng/
Title Cemented Prosthetics and Burnout Abutments IGEA | Mesa Italia
Line IGEA – prosthetic components
Materials Titanium Grade 23 · Cobalt-Chromium
Connections Narrow (M1.6, SCR-1400) · Regular (M2, SCR-1401)
Torque 30 Ncm
REF version v3-mesa-classes (S45-33)
Design system mesa-event-* (aligned to events/home leitmotiv)
Schemas Product (JSON-LD inline) + FAQ schema (JSON-LD inline)
Robots noindex, nofollow, noarchive